Warning Older Docs! - You are viewing documentation for a previous released version of RhoMobile Suite.

Code39convertToCode32 Decoder Setting

The Code39convertToCode32 Decoder Setting is used to enable conversion from Code39 to Code32 bar code. If this flag is set, the bar code is converted to Code32, and Code32 parameters are used.

Syntax

code39convertToCode32 (Decoder Setting) <META> Syntax

<META HTTP-Equiv="scanner" content="Code39ConvertToCode32:[parameter]">

code39convertToCode32 JavaScript Object Syntax:
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the code39convertToCode32.
To Set code39convertToCode32 parameters via JavaScript use the following syntax: scanner.Parameter = Value;

e.g. scanner.code39convertToCode32 = Value;
Code39convertToCode32 Ruby Object Syntax:
By default the Ruby Object 'Scanner' will exist on the current page and can be used to interact directly with the Code39convertToCode32.
To Set Code39convertToCode32 parameters via Ruby use the following syntax: Scanner.Parameter = Value

e.g. Scanner.code39convertToCode32 = Value

Parameters

Items listed in this section indicate parameters, or attributes which can be set.

Name Possible Values Description Default Value
code39convertToCode32:[Value] true/false Enables/Disables the property. Device specific

Requirements

RhoElements Version 1.0.0 or above
Supported Devices All supported devices.
Minimum Requirements Scanner or Imager module and device that supports Code39.
Persistence Transient - Decoder settings are only guaranteed to persist until the Scanner is disabled

HTML/JavaScript Examples

The following example enables the scanner to read only Code39 labels with the ConvertToCode32 property set:

<META HTTP-Equiv="scanner" Content="Code39:enabled">
<META HTTP-Equiv="scanner" Content="Code39ConvertToCode32:true">
<META HTTP-Equiv="scanner" Content="enabled">

Above example can also be written as shown below:

<META HTTP-Equiv="scanner" Content="Code39:enabled;Code32:enabled;Code39ConvertToCode32:true;enabled">

The following example enables the scanner to read only Code39 labels with the ConvertToCode32 property set:

<META HTTP-Equiv="scanner-Code39" Content="enabled">
<META HTTP-Equiv="scanner-Code39ConvertToCode32" Content="true">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">