Warning Older Docs! - You are viewing documentation for a previous released version of RhoMobile Suite.

Trioptic39redundancy Decoder Setting

The Trioptic39redundancy Decoder Setting is used to set the trioptic39 Redundancy property. If this flag is set, the bar code must be decoded twice before being accepted.

Syntax

trioptic39redundancy (Decoder Setting) <META> Syntax

<META HTTP-Equiv="scanner" content="trioptic39Redundancy:[parameter]">

trioptic39redundancy JavaScript Object Syntax:
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the trioptic39redundancy.
To Set trioptic39redundancy parameters via JavaScript use the following syntax: scanner.Parameter = Value;

e.g. scanner.trioptic39redundancy = Value;
Trioptic39redundancy Ruby Object Syntax:
By default the Ruby Object 'Scanner' will exist on the current page and can be used to interact directly with the Trioptic39redundancy.
To Set Trioptic39redundancy parameters via Ruby use the following syntax: Scanner.Parameter = Value

e.g. Scanner.trioptic39redundancy = Value

Parameters

Items listed in this section indicate parameters, or attributes which can be set.

Name Possible Values Description Default Value
trioptic39redundancy:[Value] true/false Enables/Disables the property. Device specific

Requirements

RhoElements Version 1.0.0 or above
Supported Devices All supported devices except: Enterprise Tablet.
Minimum Requirements Scanner or Imager module and device that supports trioptic39.
Persistence Transient - Decoder settings are only guaranteed to persist until the Scanner is disabled

HTML/JavaScript Examples

The following example enables the scanner to read only trioptic39 labels with the Redundancy property set

                    <META HTTP-Equiv="scanner" Content="trioptic39:enabled">
                    <META HTTP-Equiv="scanner" Content="trioptic39Redundancy:true">
                    <META HTTP-Equiv="scanner" Content="enabled">

The following example enables the scanner to read only trioptic39 labels with the Redundancy property set

                    <META HTTP-Equiv="scanner" Content="trioptic39:enabled;trioptic39Redundancy:true;enabled">

The following example enables the scanner to read only trioptic39 labels with the Redundancy property set

                    <META HTTP-Equiv="scanner-trioptic39" Content="enabled">
                    <META HTTP-Equiv="scanner-trioptic39Redundancy" Content="true">
                    <META HTTP-Equiv="scanner-enabled" Content="SCN1">
Back to Top